Glass Hardware · Stainless Steel Railing · OEM/ODM Manufacturing
Pool Fencing Hardware

Pool Fence Spigot Levelling: Adjustment vs. Shims

Pool Fence Spigot Levelling: Adjustment vs. Shims

At a glance

Compare approved spigot adjustment and designed packing details. Coordinate pool fence alignment, anchors and drainage before releasing the hardware order.

Use a pool fence spigot’s approved adjustment system or an expressly designed packing detail to achieve alignment. Do not assume loose shims can replace the intended bearing, anchoring or glass-retention arrangement. This coordination guide helps buyers distinguish product adjustment from correction of an unsuitable substrate.

Identify what is being adjusted

Is the issue the spigot base, its body or the glass position within the support? Identify the exact component from the pool fencing hardware range. A product described as adjustable may provide only a particular movement or installation function.

CRL’s adjustable spigot information illustrates a manufacturer-specific arrangement. It should not be used as instructions for another model. The base-plate versus core-drill guide helps separate mounting configurations before discussing alignment.

Round Base-Plate Glass Pool Fence Spigot - alternate product view

Catalogue illustration: Round Base-Plate Glass Pool Fence Spigot. Shown as a component reference, not an installation drawing or test result.

Adjustment and packing are different decisions

Proposed approachRequired review
Built-in adjustmentPermitted range and operating instructions
Designed packing detailMaterial, bearing, retention and connection design
Substrate correctionResponsible trade and approved repair detail
Product substitutionCompatibility and project approval

The Hilti technical resources provide anchoring context. A gap beneath a base may affect the connection, so it cannot be judged only by whether the glass looks vertical. Refer the actual detail to the responsible designer and system supplier.

Survey before ordering

Record the finished surface levels and slopes along the fence route. Show localized steps, tile build-up and gate-support locations. Our sloping-site guide explains why different positions may need different approved details.

Use NIST measurement guidance to frame survey and inspection records. Clearly distinguish a design slope from an installation deviation. A generic note saying “level on site” does not identify which component can move or what limit applies.

Threaded-Shank Core-Drill Pool Fence Spigot — Polished silver appearance concept - catalogue reference

Catalogue illustration: Threaded-Shank Core-Drill Pool Fence Spigot — Polished silver appearance concept. Shown as a component reference, not an installation drawing or test result.

Protect drainage and the surrounding finish

Coordinate the selected detail with waterproofing and drainage. The spigot drainage article helps identify questions to resolve. Packing or sealing should not obstruct an intended water path or conceal a connection that requires inspection.

IMOA coastal guidance and ASSDA cleaning guidance provide environmental and maintenance context. Specify compatible materials and follow the approved detail. Do not substitute a convenient offcut whose durability or bearing behaviour is unknown.

Check the complete pool barrier

Alignment is only part of acceptance. The CPSC barrier guidance and NSW pool information show that applicable requirements extend to the overall barrier and gate arrangement. Use the rules for the project’s jurisdiction, not a selection of convenient dimensions from different regions.

Ensure adjustments do not create an unreviewed gap or change the intended gate operation. Record final positions and required operation checks as part of handover.

Slotted-Face Glass Pool Fence Standoff — Polished silver appearance concept - product reference

Catalogue illustration: Slotted-Face Glass Pool Fence Standoff — Polished silver appearance concept. Shown as a component reference, not an installation drawing or test result.

Use separate drawing references where gate supports and fixed-panel supports require different details. Show who accepts the finished alignment and which checks must occur before covers or adjacent finishes conceal the connection. If a supplied adjustment component is missing, obtain the correct replacement instead of substituting site material without review. This keeps the delivered hardware, approved detail and final inspection record aligned throughout the installation process.

What the supplier should return

Ask for the exact model, adjustment description, installation instructions, included parts and any limits relevant to the enquiry. If the proposed detail uses separate packing, identify its designer and controlled drawing. NIST conformity assessment guidance helps define evidence appropriate to the claims being made.

For a hypothetical run containing twelve supports, record any exceptional positions separately. A detail suitable at eleven locations may not solve the twelfth. Do not allow the installer to improvise at that point simply because the remaining parts have already been delivered.

Receiving and installation records

Check that supplied adjustment parts correspond to the specified model. Retain instructions with the installation package and identify special locations on the layout. Photograph the approved assembly where it will later be covered. If a surface condition differs from the survey, resolve the discrepancy through the responsible parties before treating it as an ordinary adjustment task.

Are metal shims always acceptable? Only where the approved connection detail permits the specified packing arrangement.

Can adjustment compensate for any slope? No. Use the product’s documented limits and project detail.

Should covers be fitted before inspection? Coordinate inspection before relevant connections are concealed.

For an OEM spigot review, send the layout and surface information. Review manufacturing capabilities and request a coordinated quote identifying the hardware and any separately designed installation components.